Skip to content
SYMESTIC CP/CPK CALCULATOR

Process Capability Calculator (Cp / Cpk)

Calculate Cp, Cpk, Pp, Ppk, the expected defect rate (ppm) and the yield of your process – including the bell curve with specification limits and a centering analysis.

Input mode
Enter the mean and standard deviation directly – or paste your measurement series and let both be calculated.
Specification limits
Tolerance range of the characteristic. A single-sided USL or LSL is enough – only the corresponding index is then calculated.
Upper specification limit (USL)
Upper tolerance value
Lower specification limit (LSL)
Lower tolerance value
Nominal / target (optional)
For display in the bell curve only
Process data
Mean and sample standard deviation (s, divisor n−1) of your process.
Mean (x̄)
Process location
Standard deviation (s)
Sample standard deviation (n−1)
Measured values
Decimal separator: period. Separate values with a comma, space or line break. At least 2 values.
Number of values (n) –
Mean (x̄) –
Standard deviation (s) –
CPK
Rating
Excellent

Cp (potential)
–
Defects
–ppm
Distribution & specification limits
Normal distribution of the process with mean, USL and LSL. The red areas mark the expected share of defects outside the tolerance.
Process distribution
Defect share (outside tolerance)
The curve is a normal distribution built from your mean and standard deviation. If the mean does not sit centered between the limits, the process is not centered.
Cp (potential)
–
Tolerance width ÷ 6σ · pure spread potential without location
Cpu (upper)
–
(USL − x̄) ÷ 3σ · distance to the upper limit
Ppk (long-term)
–
Long-term · equal to Cpk here (only one σ entered)
Yield
–%
Share of parts within the tolerance
Centering: Cp vs. Cpk
Centered
Cp is the potential (spread only), Cpk is the actual value (spread + location). A large difference indicates an off-center process location.
Cp (potential)
–
Cpk (actual)
–
i
Classifying the Cpk value
Common rating bands for process capability.
–
Not capable < 1.00
Marginal 1.00–1.33
Capable 1.33–1.67
Excellent ≥ 1.67
Binding target values depend on the industry and customer (automotive often 1.33 or 1.67). We make no claim of industry-specific target figures.
Recommendations
Maintain level
Maintain & monitor capability
The process is capable. Lock in the level with statistical process control (SPC), control charts and preventive equipment maintenance.
Tool: OEE Calculator
Primary lever
Center the process
Cp is significantly larger than Cpk – the mean sits off-center. Align the process to the nominal value (tool correction, setting parameters). This raises Cpk substantially without reducing spread.
Tool: Scrap Rate / FPY Calculator
Primary lever
Reduce spread
Cp and Cpk are similarly low – the process spread (6σ) is too large for the tolerance. Reduce the spread through machine capability, material and method stability (SPC, control charts, DoE).
Tool: Scrap Rate / FPY Calculator

Get your results as a PDF

Your inputs, results and rating on one page, plus a print view and a link to your results. Free.

Enter your values and your report will be ready.

Get your free report

Your PDF downloads as soon as you submit the form. The print view and the results link are then available on this page.

Enter at least one specification limit plus the mean and standard deviation (or measured values) to calculate Cp, Cpk and the defect rate.

A free tool from SYMESTIC – Manufacturing Execution System from the cloud.
HOW THE CALCULATOR WORKS

Quick guide: calculate Cp & Cpk in 3 steps

From specification limits and process location, the tool instantly calculates Cp, Cpk, Pp, Ppk, ppm and yield. Here's how:

1

Enter the specification limits

Enter the upper (USL) and/or lower (LSL) tolerance limit. Optionally the nominal value for display in the bell curve. Single-sided tolerances are allowed.

2

Capture the process location

Enter the mean and standard deviation directly – or switch to "Raw data" in the top right and paste your measurement series. The tool calculates x̄ and s.

3

Read & interpret the result

Cp, Cpk, ppm and yield appear instantly. The bell curve shows the location relative to the tolerance, and the centering analysis shows the biggest improvement lever.

The formulas at a glance
Cp (USL − LSL) ÷ 6σ Process potential – the ratio of tolerance width to spread, without accounting for location.
Cpu / Cpl (USL−x̄)÷3σ · (x̄−LSL)÷3σ Single-sided capability indices toward the upper and lower limit respectively.
Cpk min(Cpu, Cpl) Actual capability – the more critical distance to the nearest specification limit.
Pp / Ppk like Cp / Cpk, with overall σ Long-term performance using the standard deviation of all values. With a measurement series, Cp/Cpk use the within spread (MR̄ ÷ 1.128).
ppm 10⁶ × (Φ_lower + Φ_upper) Expected defect share per million outside the specification limits under a normal distribution.
Pp/Ppk use the sample standard deviation (divisor n−1) across all measured values; in raw-data mode Cp/Cpk use σ within = MR̄ ÷ 1.128. ppm is calculated assuming a normal distribution (Φ = standard normal distribution).
WORKED EXAMPLE

Cpk calculation example: Cpk vs. Ppk on a drifting process

A lathe turns a shaft seat to 12.000 mm ± 0.025 mm. Quality measures every tenth part over one shift and records 25 diameters in production order. The cutting insert wears during the shift, so the diameter creeps upward. All values are illustrative.

Inputs

Upper specification limit (USL)12.025 mm
Lower specification limit (LSL)11.975 mm
Nominal / target12.000 mm
Input modeRaw data, 25 values in measurement order
Measured values (mm)11.988, 11.992, 11.987, 11.995, 11.990, 11.996, 11.993, 11.999, 11.994, 12.000, 11.997, 12.003, 11.998, 12.004, 12.001, 12.007, 12.002, 12.008, 12.005, 12.010, 12.006, 12.012, 12.009, 12.014, 12.011
  1. Mean and overall standard deviationx̄ = Σx ÷ 25 · s = √(Σ(x − x̄)² ÷ 24)x̄ = 12.0008 mm, s = 0.0078 mm (unrounded 0.00776 mm)
  2. Within spread from the moving rangesMR̄ = Σ|xᵢ − xᵢ₋₁| ÷ 24 = 0.117 ÷ 24 · σ_within = MR̄ ÷ 1.128MR̄ = 0.004875 mm, σ_within = 0.00432 mm
  3. Cp and Cpk with the within spreadCp = 0.050 ÷ (6 × 0.00432) · Cpu = (12.025 − 12.0008) ÷ (3 × 0.00432) · Cpl = (12.0008 − 11.975) ÷ (3 × 0.00432)Cp = 1.928, Cpu = 1.863, Cpl = 1.993, Cpk = 1.863
  4. Pp and Ppk with the overall spreadPp = 0.050 ÷ (6 × 0.00776) · Ppk = (12.025 − 12.0008) ÷ (3 × 0.00776)Pp = 1.074, Ppk = 1.038
  5. Expected defects and yieldppm = 10⁶ × [Φ((11.975 − 12.0008) ÷ 0.00776) + 1 − Φ((12.025 − 12.0008) ÷ 0.00776)]1,360 ppm outside tolerance, yield 99.86 %

Result: The calculator shows Cpk 1.863 (Excellent), Ppk 1.038, 1,360 ppm expected outside the tolerance and a yield of 99.86 %.

Reading the result: why Cpk and Ppk differ

Cpk describes the part-to-part variation of the machine. Ppk describes what the whole shift delivered. The gap comes from the drift: the first 12 parts average 11.9945 mm, the last 12 average 12.0074 mm. Each moving range covers only two neighboring parts, so a slow trend barely shows up in σ_within. The overall standard deviation contains the full trend. The ppm figure also uses the overall spread, which is why 1,360 ppm fits Ppk 1.038 and not Cpk 1.863. The centering panel flags a small offset (Cp 1.928 vs. Cpk 1.863). In this example the bigger lever is the drift: a tool offset or an earlier insert change would pull Ppk toward Cpk.

Index valueRating in the calculatorThis example
< 1.00Not capable
1.00 to 1.33MarginalPpk 1.038
1.33 to 1.67Capable
≥ 1.67ExcellentCpk 1.863

Common mistakes

  • Sorting the values before pasting them. The moving ranges then measure the gap between neighbors in a sorted list, σ_within shrinks and Cpk comes out too high. Paste the values in the order they were measured.
  • Reporting Cpk alone for a process that drifts. Cpk 1.863 next to 1,360 ppm looks contradictory to anyone who checks. Report Ppk next to it.
  • Expecting two different answers from Summary stats mode. With a single σ the calculator shows Cpk equal to Ppk. Entering x̄ = 12.0008 and s = 0.00776 here gives 1.038 for both.
  • Judging capability from too few parts. The NIST/SEMATECH handbook notes that capability indices need about 50 or more independent values to be reliable. Treat 25 values as a first look.
  • Calculating capability for a process that is not in control. Capability compares an in-control process with its limits. Check a control chart first.

Sources: NIST/SEMATECH e-Handbook of Statistical Methods, 6.1.6 What is Process Capability? · NIST/SEMATECH e-Handbook of Statistical Methods, 6.3.2.2 Individuals Control Charts (MR̄ ÷ 1.128)

FREQUENTLY ASKED QUESTIONS

Cp, Cpk & process capability – frequently asked questions

Terms, formulas and practical tips around the capability of your processes.

Cp measures the pure spread potential relative to the tolerance width and ignores the location of the mean. Cpk additionally accounts for how centered the process sits between the limits. If Cp is significantly larger than Cpk, the process is not centered – centering alone can raise Cpk.

In general, Cpk from 1.33 is considered capable (a common automotive requirement), and from 1.67 excellent. Values between 1.00 and 1.33 are marginal, and below 1.00 the process is not capable. Binding target values depend on the industry and customer.

Cpk = min[(USL − x̄) ÷ 3σ ; (x̄ − LSL) ÷ 3σ]. It is the smaller of the two single-sided indices Cpu and Cpl and therefore describes the more critical distance to the nearest specification limit.

Cp/Cpk assume the spread within the subgroups of a process in control (short-term capability). Pp/Ppk use the total spread across the entire period (long-term performance). When the standard deviation is estimated from all measured values, the values strictly speaking correspond to Pp/Ppk.

ppm (parts per million) gives the expected number of defective parts per million that lie outside the specification limits. The value is calculated from the mean and standard deviation assuming a normal distribution.

Yes. Enter only USL or only LSL. Then only the corresponding single-sided index (Cpu or Cpl) is reported as Cpk; a Cp does not exist in this case, because there is no full tolerance width.

At least one specification limit (USL or LSL) and the process location. You enter the latter either as a list of measured values (the tool calculates x̄ and s) or directly as a mean and standard deviation.

If all measured values are identical, the standard deviation is 0 and Cp/Cpk would mathematically be infinite. That is not meaningful in practice – it usually points to measurement resolution that is too coarse or too few values. Capture more and finer-resolved measured values.

The print view is available after the free unlock at: https://www.symestic.com/en-us/tools/cpk-calculator

Preview: Control Chart Template for Excel

Download · Excel

Control Chart Template for Excel

Enter measurements and track mean and range against calculated control limits.

What is inside

  • X-bar R chart for subgroups of five measurements
  • Control limits calculated from a defined reference period
  • Chart view and flags for points outside the limits
Download the control chart template (Excel)